Tripp Lite PDUMH20HVATNET Horizontal 15AMP Switched ATS/PDU

Eaton Tripp Lite series ATS PDU, 1PH, 1U, 2 C20 inputs, 12 ft cord, 3.8kW, 16A, 200-240V, 10 Outlets (8) C13 (2) C19, TAA

  • Single phase 16/20A 200-240V Auto Transfer Switch / ATS PDU
  • Enables redundant A/B power option for non-redundant network devices
  • Built-in LX Platform Network Interface
  • 1U horizontal rackmount; 10 outlets (8 C13 switched / 2 C19 unswitched)
  • Individually switched outlets, network interface and 2 digit visual current meter
  • TAA Compliant
  • 2-year advanced replacement warranty

Resource & Downloads
Owner’s Manual for Switched/Metered Rack PDU with Automatic Transfer Switch (Multi-language)
PDU Buying Guide
PDU Installation Options

Contact Us for Pricing

Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable.

Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS power protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite Smart Online series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. Built-in LX Platform network management interface card. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. OptionalEnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3,telnet, SSH, FTP, DHCP and NTP.? 200-240V 16/20A Automatic Transfer Switch (ATS) / Switched PDU (Agency de-rated to 16A continuous)? Enables redundant A/B power option for single-corded network devices

  • 2 digit display reports power consumption in amps
  • 1U horizontal rackmount form factor
  • 10 outlets (8 C13 switched / 2 C19 unswitched)
  • Set of Plug-lock output power cable retention sleeves prevent accidental disconnection of connected devices
  • Two C20 inlets for separate Primary and Secondary inputs; two 3.7 m C20 input cables included
  • ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
  • ATS configurations enable hot-swappable UPS protection when used with a single UPS and redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time)
  • Advanced ATS configurations utilizing separate mains circuits, backup generators and separate out of phase utility power grid feeds are supported
  • On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
  • 2-7 millisecond transfer time
  • Switched outlets and ethernet interface supports individual outlet control on a real-time or programmable basis and user-specified alarm notification thresholds for all reported site power conditions
  • LX Platform interface allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH
  • Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities
  • Outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first energized
  • LEDs confirm power availability on both input lines and for each output receptacle

Eaton Tripp Lite series ATS PDU Specifications

Category Specification Details
General Product Name Tripp Lite PDUMH20HVATNET Horizontal Switched ATS/PDU
Model PDUMH20HVATNET
Product Type Automatic Transfer Switch / Switched PDU
Brand Tripp Lite
Capacity 3.8 kW
Form Factor 1U Horizontal Rackmount
Mounting Direction Horizontal
Material Metal
ATS Type Automatic Transfer Switch
Input Input Voltage 200–240V AC
Input Current 16A continuous / 20A nominal
Phase Single Phase
Frequency 50/60 Hz
Input Connectors 2 × C20
Input Cables 2 × 3.7 m C20 cables included
Power Source Primary and Secondary Inputs
Cord Length 3.7 m / 12 ft
Output Output Receptacles 10
Switched Outlets 8 × C13
Unswitched Outlets 2 × C19
Output Voltage 200–240V AC
PDU Plug Type C20
Transfer Time 2–7 ms
Sequential Power-On 250 ms intervals
ATS Features Automatic Transfer Yes
Primary/Secondary Power Sources Yes
Power Quality Monitoring Yes
ATS Processor Continuously monitors both input sources
A/B Power Redundancy Supported
UPS Redundancy Supported
Generator Compatibility Supported
Separate Utility Feeds Supported
Monitoring & Management Network Interface Built-in LX Platform
SNMP Yes
Remote Web Management Yes
Email Notifications Yes
Telnet Supported
SSH Supported
HTTP/HTTPS Supported
FTP Supported
DHCP Supported
NTP Supported
Ethernet 10/100 Mbps Auto-Sensing
Current Meter 2-Digit Visual Current Display
Individual Outlet Control Yes
Programmable Outlet Control Yes
Protection & Features Outlet Switching Individually Switched
Cable Retention Plug-Lock Cable Retention Sleeves
Input Status LEDs Yes
Output Status LEDs Yes
Alarm Thresholds User-Configurable
Environmental Monitoring Supported with Optional EnviroSense2
Physical Specifications Rack Height 1U
Dimensions (H × W × D) 1.72 × 17.33 × 14.77 in
Approx. Dimensions (H × W × D) 43.7 × 440.2 × 375.2 mm
Weight 7.71 kg
Compliance & Warranty TAA Compliant Yes
RoHS Yes
CE Marked Yes
FCC Class A
Certifications UL 60950-1, NOM, CSA C22.2
Warranty 2-Year Limited Warranty
Applications Recommended Use Data Centres, Server Racks, Network Equipment, IT Infrastructure, Telecommunications and Critical Power Distribution