Description
TRIPP LITE Provides UL 60601-1 compliant, medical-grade 700VA/450W power backup, ideal for use in patient-care vicinities. The built-in isolation transformer offers full isolation while maintaining AC surge protection in all modes.
- Supports a half load up to 36 minutes; full load up to 14.5 minutes
- Six IEC320 C13 hospital-grade outlets and IEC320 C14 hospital-grade plug
- Leakage current less than 100 microamps
- Approved for use within the Patient Care Vicinity
- Approved to EN60601-1-2:2015, 4th Edition
- 340 joule surge suppression rating protects connected equipment
- Alarm mute/alarm quiet control is ideal for use around patients
2-year warranty
Specifications
OVERVIEW
UPC Code | 037332140418 |
UPS Type | Line-Interactive |
OUTPUT
Output Volt Amp Capacity (VA) | 700 |
Output Watt Capacity (Watts) | 450 |
Nominal Voltage Details | 230v nominal inverter output voltage |
Frequency Compatibility | 50 / 60 Hz |
Frequency Compatibility Details | Automatic frequency selection |
Output Voltage Regulation (Line Mode) | -18%, +8% |
Output AC Waveform (Battery Mode) | PWM sine wave |
Nominal Output Voltage(s) Supported | 220V; 230V; 240V |
Output Receptacles | (6) C13 |
Individually Controllable Load Banks | No |
INPUT
Rated input current (Maximum Load) | 3.6A |
Nominal Input Voltage(s) Supported | 230V AC |
UPS Input Connection Type | C14 inlet |
UPS Input Cord Length (ft.) | 0.50 |
UPS Input Cord Length (m) | 0.2 |
Recommended Electrical Service | 10A 230V |
Voltage Compatibility (VAC) | 230 |
Input Phase | Single-Phase |
BATTERY
Full Load Runtime (min.) | 14.5 min. (450w) |
Half Load Runtime (min.) | 36 min. (225w) |
DC System Voltage (VDC) | 36 |
Battery Recharge Rate (Included Batteries) | Less than 3.6 hours from 10% to 90% (typical, full load discharge) |
Internal UPS Replacement Battery Cartridge | RBC36SLT |
Battery Access | Battery access door allows hot swap battery replacement without powering connected equipment off |
Typical Battery Lifespan | 3-6 years, depending on usage |
Expandable Runtime | No |
VOLTAGE REGULATION
Voltage Regulation Description | Line interactive UPS offers 2 boost levels of brownout correction and a single level of overvoltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 155 to 274V AC |
Overvoltage Correction | Input voltages between 206 and 245V AC are reduced by 9% |
Undervoltage Correction | Input voltages between 183 and 199 are boosted by 10% |
Severe Undervoltage Correction | Input voltages between 155 and 182 are boosted by 21% |
USER INTERFACE, ALERTS & CONTROLS
Switches | Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions |
Audible Alarm | 3 function audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps) and low battery (continuous tone). Audible Alarm is factory muted for silent operation; Audible alarm can be restored to indicate power failure, overload conditions and Low Battery events, using our Free PowerAlert UPS management software. |
LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating | 340 |
EMI / RFI AC Noise Suppression | Yes |
AC Suppression Response Time | Instantaneous |
PHYSICAL
Cooling Method | Cooling via rear-exit cooling fan |
Installation Form Factors Supported with Optional Accessories | Wallmount ( UPSWM – tower mounting kit) |
Primary Form Factor | Tower |
Primary UPS Depth (mm) | 229 |
Primary UPS Height (mm) | 325 |
Primary UPS Width (mm) | 191 |
Shipping Dimensions (hwd / cm) | 46.99 x 30.99 x 33.99 |
Shipping Weight (kg) | 20.59 |
UPS Housing Material | PVC |
UPS Power Module Dimensions (hwd, cm) | 32.51 x 19.05 x 22.86 |
UPS Power Module Weight (kg) | 19.10 |
ENVIRONMENTAL
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity | 0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) | 208.6 |
Battery Mode BTU / Hr. (Full Load) | 189.1 |
COMMUNICATIONS
Communications Interface | USB; DB9 Serial |
LINE / BATTERY TRANSFER
Transfer Time | 5 milliseconds |
Low Voltage Transfer to Battery Power (Setpoint) | 155 |
High Voltage Transfer to Battery Power (Setpoint) | 274 |
SPECIAL FEATURES
Grounding Lug | Equipotential connection (back panel grounding lug) |
Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
CERTIFICATIONS
UPS Certifications | CE; Tested to UL60601-1 (medical grade) |
WARRANTY
Product Warranty Period (International) | 2-year warranty |